Ever had MASS stop working while working on a design? You aren’t alone!
In any windows architecture application, there is a limit of 10,000 GDI objects. Internally, there a number of these crated with every design and population of each results screen. Unfortunately, there are a number of these that are not properly “cleaned up” so using the same MASS window for an extended period of time will trigger this crash.
The release of MASS Version 4.0 has mitigated the problem but there are always residual GDI objects between every design. Our recommendation in dealing with this issue is to regularly save your work.
A full video demonstrating this and how to check your GDI object status is shown below:
This issue is most likely to occur when designing a shearline or multi-storey shear wall module as these assemblage options coordinate the creation of several shear wall elements internally, triggering the creation of additional GDI objects.
If you have any questions, please do not hesitate to contact MASS support.
As always, feel free to contact us if you have any questions at all. CMDC is the authorized service provider for the MASS software which is a joint effort of between CCMPA and CMDC.
Related Posts
Deflection Check for Out-of-Plane Walls
- Posted by Gurparam Kang
- 0 comments
Bug Notification: Non-Seismic Lateral Companion Loads Amplified for Seismic Effects
- Posted by Brad Crumb
- 0 comments
Bug Notification: Out-of-Plane Shear Resistance checked only at location of maximum shear
- Posted by Brad Crumb
- 1 comment
Known Bugs in MASS
- Posted by Brad Crumb
MASS Version 4.0 is now available – adds multi-storey design and more earthquake design options
- Posted by Brad Crumb
MASS Bug Notification: Maximum Allowable Axial Load Overestimated for some Shear Walls with Fully Grouted Flanges
- Posted by Brad Crumb
MASS Bug Notification: Saved Projects and French Canadian Language Settings
- Posted by Brad Crumb
Understanding the Minimum Boundary Element Length Limits on Strain
- Posted by Brad Crumb
- 1 comment
Updated Pricing Announced for all MASS Licenses
- Posted by Brad Crumb
What is the Difference Between Fixed and Cantilever Pier Designations in a Shearline?
- Posted by Brad Crumb
How to model individual storeys of a multi-storey shear wall within MASS
- Posted by Brad Crumb
What is the Difference Between Height and Total Height when Designing a Shear Wall in MASS?
- Posted by Brad Crumb