Version 4.0 Feature Spotlight: Ductility Verification
Moderately Ductile and Ductile shear walls can now be designed within MASS to satisfy the ductility verification (required by CSA S304-14)
Any designers struggling with post-disaster strictures or the axial load limitations of conventional construction masonry will be happy to know that MASS Version 4.0 has the ability to perform this check as part of the new seismic design process.
The software automatically detects when the ductility verification is required and in cases where boundary elements are used, can even take advantage of higher maximum compressive strains.
This post is part of a short series highlighting what is new to MASS Version 4.0. The full change log can be seen by clicking here.
Was this post helpful?
Let us know if you liked the post. That’s the only way we can improve.
Related Posts
Bug Notification: Drift Values instead of Elastic Deflections used for Inelastic Rotational Demand
The current MASS approach in Version 4.0 means that linear elastic deflections are over-corrected in a way that largely overestimates d...
Version 4.0 Feature Spotlight: Simplified National Building Code Seismic Design
Added to the 2015 National Building Code of Canada is a new design pathway that can be used for areas with very low seismic hazard leve...
MASS Version 4.0 is now available – adds multi-storey design and more earthquake design options
Version 4.0 adds to the scope of what MASS is capable of handling
It's real, and it's spectacular! We are very excited to anno...
MASS Version 4.0 Release Notification
Version 4.0 adds to the scope of what MASS is capable of handling
It's real, and it's spectacular! We are very excited to anno...
Version 4.0 Feature Spotlight: Online Activation Restored!
Oh yes we did! The title speaks for itself and engineers (or their I.T. professionals) everywhere rejoice
Due to some behind the scene...
Version 4.0 Feature Spotlight: New Zoom and Pan Functionality for Drawings
New to Version 4 is a more intuitive way to navigate drawings
The interface for navigating drawings using anything other than the scro...
Why ISN’T the Factored Shear Force Scaled up for a Seismic Design?
While you might not have expected it, MASS has it's reasons for leaving your factored shear alone - even with earthquake loads applied
...
Why is the Factored Shear Force Scaled Up for Seismic Considerations on a Shear Wall Design?
Explaining these clauses and how they are applied
Questions about the seismic effects on shear resistance? Click here for a ...
How MASS Aligns Vertical Bars in a Multi-Storey Shear Wall
The method used by MASS to get bars to align is fairly complicated but gets the job done.
One early point of feedback in the...
Understanding the Minimum Boundary Element Length Limits on Strain
While not explicitly listed as a strain limit, the minimum boundary element size can have a large effect on how high maximum compressiv...