07 May Software Tips Version 4.0 Feature Spotlight: New Zoom and Pan Functionality for Drawings June 5, 2020 Posted by Brad Crumb 0 comments New to Version 4 is a more intuitive way to navigate drawings The interface for navigating drawings using anything other than the scro... Continue reading
22 Apr Technical Multi-Storey Drift Example: Done by hand! (Video) May 27, 2020 Posted by Brad Crumb 2 comments Have questions about how MASS Determines drift values? Have no fear! (and prepared to dive deep into hand calculations) Th... Continue reading
13 Apr Technical Why are different envelope curves plotted for the same Group? May 12, 2020 Posted by Brad Crumb 0 comments For the most part, there is one envelope curve shared between storeys with the same cross section... with one exception! We ... Continue reading
13 Apr Technical Why ISN’T the Factored Shear Force Scaled up for a Seismic Design? May 12, 2020 Posted by Brad Crumb 0 comments While you might not have expected it, MASS has it's reasons for leaving your factored shear alone - even with earthquake loads applied ... Continue reading
07 Apr Technical Why is masonry shear resistance reduced for seismic effects in a shear wall design? May 12, 2020 Posted by Brad Crumb 0 comments When Shear Resistance is Reduced, Have No Fear! Seeing the masonry component of a shear wall's shear resistance is a part of everyday ... Continue reading
01 Apr Technical Bonus Post: What happens when you treat a Multi-Storey Design as an Element when Increasing Factored in-Plane Shear ? May 12, 2020 Posted by Brad Crumb 0 comments Does changing the analysis method effect the final results? The process shown here is how MASS internally performs the analy... Continue reading
01 Apr Technical Checking Vf,seismic for a Shear Wall Element May 12, 2020 Posted by Brad Crumb 0 comments Taking seismic effects into account in MASS can be confusing. Seeing factored shear forces scaled up by over 100% in some cases may see... Continue reading
01 Apr Technical Why is the Factored Shear Force Scaled Up for Seismic Considerations on a Shear Wall Design? April 23, 2021 Posted by Brad Crumb 1 comment Explaining these clauses and how they are applied Questions about the seismic effects on shear resistance? Click here for a ... Continue reading
01 Apr Technical Checking Vf,seismic for a Multi-Storey Shear Wall May 12, 2020 Posted by Brad Crumb 0 comments Taking seismic effects into account in MASS can be confusing. Seeing factored shear forces scaled up by over 100% in some cases may see... Continue reading
13 Apr Technical Why are different envelope curves plotted for the same Group? May 12, 2020 Posted by Brad Crumb 0 comments For the most part, there is one envelope curve shared between storeys with the same cross section... with one exception! We ... Continue reading
13 Apr Technical Why ISN’T the Factored Shear Force Scaled up for a Seismic Design? May 12, 2020 Posted by Brad Crumb 0 comments While you might not have expected it, MASS has it's reasons for leaving your factored shear alone - even with earthquake loads applied ... Continue reading
07 Apr Technical Why is masonry shear resistance reduced for seismic effects in a shear wall design? May 12, 2020 Posted by Brad Crumb 0 comments When Shear Resistance is Reduced, Have No Fear! Seeing the masonry component of a shear wall's shear resistance is a part of everyday ... Continue reading
01 Apr Technical Bonus Post: What happens when you treat a Multi-Storey Design as an Element when Increasing Factored in-Plane Shear ? May 12, 2020 Posted by Brad Crumb 0 comments Does changing the analysis method effect the final results? The process shown here is how MASS internally performs the analy... Continue reading
01 Apr Technical Checking Vf,seismic for a Shear Wall Element May 12, 2020 Posted by Brad Crumb 0 comments Taking seismic effects into account in MASS can be confusing. Seeing factored shear forces scaled up by over 100% in some cases may see... Continue reading
01 Apr Technical Why is the Factored Shear Force Scaled Up for Seismic Considerations on a Shear Wall Design? April 23, 2021 Posted by Brad Crumb 1 comment Explaining these clauses and how they are applied Questions about the seismic effects on shear resistance? Click here for a ... Continue reading
01 Apr Technical Checking Vf,seismic for a Multi-Storey Shear Wall May 12, 2020 Posted by Brad Crumb 0 comments Taking seismic effects into account in MASS can be confusing. Seeing factored shear forces scaled up by over 100% in some cases may see... Continue reading
30 Mar Bug Notification, Software, Technical MASS Bug Notification: Maximum Allowable Axial Load Overestimated for some Shear Walls with Fully Grouted Flanges February 8, 2021 Posted by Brad Crumb Understanding the issue, when it can come up, and what can be done to account for it When software bugs are found, notifications are p... Continue reading
30 Mar Bug Notification, Software, Troubleshooting MASS Bug Notification: Software Crashes Unexpectedly March 30, 2020 Posted by Brad Crumb Ever had MASS stop working while working on a design? You aren't alone! In any windows architecture application, there is a limit of 1... Continue reading
18 Feb Software Tips How MASS Aligns Vertical Bars in a Multi-Storey Shear Wall December 2, 2020 Posted by Brad Crumb 1 comment The method used by MASS to get bars to align is fairly complicated but gets the job done. One early point of feedback in the... Continue reading