Please ensure Javascript is enabled for purposes of website accessibility Latest Software Blog Posts - Page 3 of 6 - MASS User Documentation
Need Extra Assistance?

Contact Us!

MASS User Documentation MASS User Documentation
BUY MASS™
Search
Menu
MASS User Documentation MASS User Documentation
Search
  • Home
  • Getting Started
    • Introduction to MASS
    • Installation Guide
    • Activation Guide
    • Computer Requirements
    • Where to Get Help
    • What’s new in Version 4.2
      • Version History and Change Log
  • Getting to Know MASS
    • General Overview
    • Assemblage Modules
    • Creating a Project File
    • Adding, Renaming, and Removing
    • Saving a Project File
    • User Interface Overview
    • Design Steps
    • A Complete Design
    • Analysis
    • Printing
    • Masonry Self-Weight
    • Masonry Unit Database
  • Modules
    • Beams
      • Introduction
      • Design Steps
      • A Complete Design
      • Design Strategy
    • Out-of-Plane Walls
      • Introduction
      • Design Steps
      • A Complete Design
      • Loads Analysis Results
      • Design Strategy
      • P-M Interaction Diagram
    • Shear Walls
      • Introduction
      • Design Steps
      • Boundary Elements
      • A Complete Design
      • Load Analysis Results
      • Design Strategy
      • Element Deflection
      • Self-Weight
      • Interaction Diagram
    • Multi-Storey Shear Walls
      • Introduction
      • Design Steps
      • Design Strategy
      • Load Distribution
      • Drift
    • Shearline
      • Introduction
      • Design Steps
      • Load Distribution
      • Pier Generation
      • Design Strategy
  • FAQs
    • Technical FAQ
    • Excluded Features
    • Known Bugs
    • Additional Resources
  • Latest Updates
    ANNOUNCEMENTS
    BUG NOTIFICATION
    LICENSING
    NEWS
    SOFTWARE
    SOFTWARE TIPS
    SOFTWARE
    TROUBLESHOOTING
    07 May
    Software Tips

    Version 4.0 Feature Spotlight: New Zoom and Pan Functionality for Drawings

    • June 5, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    New to Version 4 is a more intuitive way to navigate drawings The interface for navigating drawings using anything other than the scro...

    Continue reading

    22 Apr
    Technical

    Multi-Storey Drift Example: Done by hand! (Video)

    • May 27, 2020
    • Posted by author-avatar Brad Crumb
    • 2 comments
    Have questions about how MASS Determines drift values? Have no fear! (and prepared to dive deep into hand calculations)   Th...

    Continue reading

    13 Apr
    Technical

    Why are different envelope curves plotted for the same Group?

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    For the most part, there is one envelope curve shared between storeys with the same cross section... with one exception!   We ...

    Continue reading

    13 Apr
    Technical

    Why ISN’T the Factored Shear Force Scaled up for a Seismic Design?

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    While you might not have expected it, MASS has it's reasons for leaving your factored shear alone - even with earthquake loads applied ...

    Continue reading

    07 Apr
    Technical

    Why is masonry shear resistance reduced for seismic effects in a shear wall design?

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    When Shear Resistance is Reduced, Have No Fear! Seeing the masonry component of a shear wall's shear resistance is a part of everyday ...

    Continue reading

    01 Apr
    Technical

    Bonus Post: What happens when you treat a Multi-Storey Design as an Element when Increasing Factored in-Plane Shear ?

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    Does changing the analysis method effect the final results?   The process shown here is how MASS internally performs the analy...

    Continue reading

    01 Apr
    Technical

    Checking Vf,seismic for a Shear Wall Element

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    Taking seismic effects into account in MASS can be confusing. Seeing factored shear forces scaled up by over 100% in some cases may see...

    Continue reading

    01 Apr
    Technical

    Why is the Factored Shear Force Scaled Up for Seismic Considerations on a Shear Wall Design?

    • April 23, 2021
    • Posted by author-avatar Brad Crumb
    • 1 comment
    Explaining these clauses and how they are applied   Questions about the seismic effects on shear resistance? Click here for a ...

    Continue reading

    01 Apr
    Technical

    Checking Vf,seismic for a Multi-Storey Shear Wall

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    Taking seismic effects into account in MASS can be confusing. Seeing factored shear forces scaled up by over 100% in some cases may see...

    Continue reading

    • Contact Us

    Latest Software Blog Posts

    HomeBlogPage 3
    Close
    Generic selectors
    Exact matches only
    Search in title
    Search in content
    Post Type Selectors
    Categories
    • Announcements
    • Bug Notification
    • Licensing
    • News
    • Software
    • Software Tips
    • Technical
    • Troubleshooting
    13 Apr
    Technical

    Why are different envelope curves plotted for the same Group?

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    For the most part, there is one envelope curve shared between storeys with the same cross section... with one exception!   We ...

    Continue reading

    13 Apr
    Technical

    Why ISN’T the Factored Shear Force Scaled up for a Seismic Design?

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    While you might not have expected it, MASS has it's reasons for leaving your factored shear alone - even with earthquake loads applied ...

    Continue reading

    07 Apr
    Technical

    Why is masonry shear resistance reduced for seismic effects in a shear wall design?

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    When Shear Resistance is Reduced, Have No Fear! Seeing the masonry component of a shear wall's shear resistance is a part of everyday ...

    Continue reading

    01 Apr
    Technical

    Bonus Post: What happens when you treat a Multi-Storey Design as an Element when Increasing Factored in-Plane Shear ?

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    Does changing the analysis method effect the final results?   The process shown here is how MASS internally performs the analy...

    Continue reading

    01 Apr
    Technical

    Checking Vf,seismic for a Shear Wall Element

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    Taking seismic effects into account in MASS can be confusing. Seeing factored shear forces scaled up by over 100% in some cases may see...

    Continue reading

    01 Apr
    Technical

    Why is the Factored Shear Force Scaled Up for Seismic Considerations on a Shear Wall Design?

    • April 23, 2021
    • Posted by author-avatar Brad Crumb
    • 1 comment
    Explaining these clauses and how they are applied   Questions about the seismic effects on shear resistance? Click here for a ...

    Continue reading

    01 Apr
    Technical

    Checking Vf,seismic for a Multi-Storey Shear Wall

    • May 12, 2020
    • Posted by author-avatar Brad Crumb
    • 0 comments
    Taking seismic effects into account in MASS can be confusing. Seeing factored shear forces scaled up by over 100% in some cases may see...

    Continue reading

    30 Mar
    Bug Notification, Software, Technical

    MASS Bug Notification: Maximum Allowable Axial Load Overestimated for some Shear Walls with Fully Grouted Flanges

    • February 8, 2021
    • Posted by author-avatar Brad Crumb
    Understanding the issue, when it can come up, and what can be done to account for it When software bugs are found, notifications are p...

    Continue reading

    30 Mar
    Bug Notification, Software, Troubleshooting

    MASS Bug Notification: Software Crashes Unexpectedly

    • March 30, 2020
    • Posted by author-avatar Brad Crumb
    Ever had MASS stop working while working on a design? You aren't alone! In any windows architecture application, there is a limit of 1...

    Continue reading

    18 Feb
    Software Tips

    How MASS Aligns Vertical Bars in a Multi-Storey Shear Wall

    • December 2, 2020
    • Posted by author-avatar Brad Crumb
    • 1 comment
    The method used by MASS to get bars to align is fairly complicated but gets the job done.   One early point of feedback in the...

    Continue reading

    Load more posts
    Loading...
    Stay up-to-date on the latest releases, updates and bug notifications!

    Sign up for Updates today

    JOIN NOW
    Name
    Simplify and accelerate the masonry engineering process with MASS. Design structural masonry elements in accordance with Canadian Codes and Standards
    SUPPORTED BY NMDP

    National Masonry Design Programs is a joint venture partnership between CMDC and CCMPA  in an effort to support the engineering design community. Click here to learn more.

    Head Office

    Canada Masonry Design Centre
    360 Superior Blvd.
    Mississauga, ON
    Canada L5T 2N7

    Tech Support

    Phone: 888.338.3336
    Toronto: 
    905.564.0666
    Fax: 905.564.5744
    mass@canadamasonrycentre.com

    ©

    Masonry Analysis Structural Systems - National Masonry Design Programs. All Rights Reserved.
    Created by Mainstream Marketing | Privacy Policy | Terms & Conditions
    Start typing to see posts you are looking for.
    • Home
    • Getting Started
      • Introduction to MASS
      • Installation Guide
      • Activation Guide
      • Computer Requirements
      • Where to Get Help
      • What’s new in Version 4.2
        • Version History and Change Log
    • Getting to Know MASS
      • General Overview
      • Assemblage Modules
      • Creating a Project File
      • Adding, Renaming, and Removing
      • Saving a Project File
      • User Interface Overview
      • Design Steps
      • A Complete Design
      • Analysis
      • Printing
      • Masonry Self-Weight
      • Masonry Unit Database
    • Modules
      • Beams
        • Introduction
        • Design Steps
        • A Complete Design
        • Design Strategy
      • Out-of-Plane Walls
        • Introduction
        • Design Steps
        • A Complete Design
        • Loads Analysis Results
        • Design Strategy
        • P-M Interaction Diagram
      • Shear Walls
        • Introduction
        • Design Steps
        • Boundary Elements
        • A Complete Design
        • Load Analysis Results
        • Design Strategy
        • Element Deflection
        • Self-Weight
        • Interaction Diagram
      • Multi-Storey Shear Walls
        • Introduction
        • Design Steps
        • Design Strategy
        • Load Distribution
        • Drift
      • Shearline
        • Introduction
        • Design Steps
        • Load Distribution
        • Pier Generation
        • Design Strategy
    • FAQs
      • Technical FAQ
      • Excluded Features
      • Known Bugs
      • Additional Resources
    • Latest Updates
    • Contact Us
    Sidebar