30 Jan Technical Conventional Construction Comprehensive Analysis Example January 31, 2024 Posted by Gurparam Kang 0 comments Are you curious about how MASS conducts a detailed analysis of Conventional Construction walls through its Comprehensive Analysis metho... Continue reading
29 Jan Technical Change Notification: Axial Load Limit for Conventional Construction Walls January 31, 2024 Posted by Gurparam Kang 0 comments The axial load limit for a Conventional Construction shear wall with a seismic hazard exceeding 0.35, currently in MASS, complicates th... Continue reading
29 Jan Announcements MASS Version 4.2 Release Notification March 18, 2024 Posted by Gurparam Kang 0 comments Version 4.2 adds to the scope of what MASS is capable of handling We are very excited to announce this new release, available immediat... Continue reading
10 Jan Software, Software Tips, Technical Deflection Check for Out-of-Plane Walls January 30, 2023 Posted by Gurparam Kang 0 comments When designing out-of-plane cantilever walls subjected to lateral loads, the MASS software can be used to check the wall’s deflection a... Continue reading
11 Jun Bug Notification, Technical Change Notification: Lambda Values for Beam Density and Shear June 25, 2021 Posted by Brad Crumb 0 comments Deviating from the CSA Standards to better reflect practical design While the existing implementation for MASS Versions 3.0 ... Continue reading
21 Apr Bug Notification, Technical Bug Notification: Drift Values instead of Elastic Deflections used for Inelastic Rotational Demand April 21, 2021 Posted by Brad Crumb 0 comments The current MASS approach in Version 4.0 means that linear elastic deflections are over-corrected in a way that largely overestimates d... Continue reading
19 Apr Bug Notification, Technical Bug Notification: Seismic reinforcement spacings applied to all shear walls resisting an earthquake load August 11, 2021 Posted by Brad Crumb 0 comments While most seismic requirements are triggered by the application of an earthquake load, MASS is too stringent on it's reinforcement spa... Continue reading
09 Mar Bug Notification Notification: Seismic Shear Forces Amplification Change for Elements Above Critical Section June 17, 2021 Posted by Brad Crumb 0 comments The storey-by-storey design approach currently in MASS can excessively amplify shear forces beyond expected results In cases... Continue reading
08 Feb Bug Notification Bug Notification: Non-Seismic Lateral Companion Loads Amplified for Seismic Effects April 19, 2021 Posted by Brad Crumb 0 comments Be aware of this for shear wall designs resisting lateral earth pressures In cases where a bug or other issue is found in th... Continue reading
13 Nov Technical Full Multi-Storey Design Process Diagram for the high achievers out there November 13, 2019 Posted by Brad Crumb 0 comments Nerd Alert: This isn't need to know information but may be useful for someone out there who is digging into the MASS Multi-Storey Shear... Continue reading
16 May Licensing, News Updated Pricing Announced for all MASS Licenses January 6, 2021 Posted by Brad Crumb After five years of consistent renewal pricing, a small change has been applied to all renewal and purchase prices This arti... Continue reading
03 Nov Software Tips, Technical How to model individual storeys of a multi-storey shear wall within MASS January 6, 2021 Posted by Brad Crumb In the absence of a true multi-storey MASS module (Update: added in V4.0), there are steps that can be taken to use MASS effectively fo... Continue reading
02 Nov Software Tips, Technical What is the Difference Between Height and Total Height when Designing a Shear Wall in MASS? January 6, 2021 Posted by Brad Crumb Understanding the Total Height input when using MASS can add considerable moment capacity to a shear wall design This articl... Continue reading
20 Sep News, Software What is MASS Version 2.2.1? (and why you should install it) January 6, 2021 Posted by Brad Crumb With the release of MASS Version 3.0, the previous edition of MASS has gotten a small adjustment This article originally was... Continue reading
06 Mar Software Tips, Technical, Troubleshooting Why does MASS use unreinforced analysis for a design with reinforcement? January 6, 2021 Posted by Brad Crumb Adding steel to a wall design does not necessarily mean that the steel is being used. This article covers the basics on how to avoid a... Continue reading