12 Jan Announcements, Software Tips Version 4.0 Feature Spotlight: Ductility Verification January 11, 2021 Posted by Brad Crumb 0 comments Moderately Ductile and Ductile shear walls can now be designed within MASS to satisfy the ductility verification (required by CSA S304-... Continue reading
11 Jan Announcements, Software Tips Version 4.0 Feature Spotlight: Simplified National Building Code Seismic Design February 9, 2021 Posted by Brad Crumb 0 comments Added to the 2015 National Building Code of Canada is a new design pathway that can be used for areas with very low seismic hazard leve... Continue reading
11 Nov Bug Notification, Technical Bug Notification: Out-of-Plane Shear Resistance checked only at location of maximum shear January 13, 2021 Posted by Brad Crumb 1 comment While not always calculated at the critical location of a wall, out-of-plane walls are typically governed by flexure. In cas... Continue reading
11 Nov Bug Notification, Troubleshooting Known Bugs in MASS April 6, 2021 Posted by Brad Crumb Bugs are found from time to time and in our effort to be trustworthy and transparent, they are posted here as well as appearing on the ... Continue reading
27 Jul News, Software MASS Version 4.0 is now available – adds multi-storey design and more earthquake design options July 27, 2020 Posted by Brad Crumb Version 4.0 adds to the scope of what MASS is capable of handling It's real, and it's spectacular! We are very excited to anno... Continue reading
27 Jul Announcements MASS Version 4.0 Release Notification July 28, 2020 Posted by Brad Crumb 1 comment Version 4.0 adds to the scope of what MASS is capable of handling It's real, and it's spectacular! We are very excited to anno... Continue reading
05 Jun Software Tips Version 4.0 Feature Spotlight: Online Activation Restored! June 5, 2020 Posted by Brad Crumb 0 comments Oh yes we did! The title speaks for itself and engineers (or their I.T. professionals) everywhere rejoice Due to some behind the scene... Continue reading
25 May Technical Why doesn’t MASS consider Type 6 Structural Irregularities? August 13, 2020 Posted by Brad Crumb 1 comment With MASS Version 4.0 moving into Multi-Storey Shear Wall design, why doesn't the software check for something that seems squarely with... Continue reading
20 May Technical Failed the Ductility Verification? How to Pick a Higher εmu, the Maximum Compressive Strain July 27, 2020 Posted by Brad Crumb 1 comment The addition of boundary elements to MASS Version 4 (as well as CSA S304-14) means that failing a ductility verification is not the end... Continue reading
02 Nov Software Tips, Technical What is the Difference Between Height and Total Height when Designing a Shear Wall in MASS? January 6, 2021 Posted by Brad Crumb Understanding the Total Height input when using MASS can add considerable moment capacity to a shear wall design This articl... Continue reading
10 Apr Software Tips, Technical, Troubleshooting Masonry Beam Design: How to design beams with what might seem like less than the minimum reinforcement ratio April 6, 2021 Posted by Brad Crumb 0 comments When a design seems like it might not meet minimum steel, all hope is not lost While there is no way around satisfying the minimum ste... Continue reading
06 Mar Software Tips, Technical, Troubleshooting Why does MASS use unreinforced analysis for a design with reinforcement? January 6, 2021 Posted by Brad Crumb Adding steel to a wall design does not necessarily mean that the steel is being used. This article covers the basics on how to avoid a... Continue reading
12 Jan Software Tips, Technical, Troubleshooting How to use MASS to Design Walls that Span Horizontally January 11, 2021 Posted by Brad Crumb Getting the most out of MASS is easy once you understand how to model your design within the software This article originall... Continue reading
17 Nov Software Tips, Technical, Troubleshooting Understanding the χ factor and how it can help with masonry beam design January 6, 2021 Posted by Brad Crumb 0 comments Beam design can be tricky but understanding the factors at play makes it easy to design beams with masonry This article orig... Continue reading
11 Nov Software Tips, Technical, Troubleshooting Bars spaced at 200mm? Consider fully grouting your walls January 6, 2021 Posted by Brad Crumb 0 comments MASS might be telling you to place a bar in every cell. Maybe you need that much steel... but what if you don't? This articl... Continue reading
26 Aug Software Tips, Technical Why can’t I add stirrups to my masonry beam? January 6, 2021 Posted by Brad Crumb Want to place stirrups but the options are greyed out? This is one of the most common question we get having to do with masonry beam d... Continue reading